The T 11 transformer is of- the shell-type single outlet ignition transformer with one secondary and one primary winding. The secondary winding has one terminal earthed. The insulator is manufactured directly when casting the coils.
APPLICATION
The T11 series transformer is suitable for burners firing gas of any capacity. If only one ignition electrode is required, it can be used too for od burners. Its manufacturing features also allow fittings on burners with or without covers.
The distance between the electrode points must be such to ensure ignition occurs with the minimum input voltage value.
TECHNICAL SPECIFICATIONS
Primary voltage: 220 V
Intermittence on 3 minutes: 33 %
Frequency: 50 Hz
Secondary voltage: 1×9 kV
Primary current: 1.1 A
Secondary current: 20 mA
Power consumption: 240 VA
Feed cable: 55 cm
Casing: Metallic covers
Insulator: Epoxy-Resin
H.T. terminals: Rajah or self-threading